Item Comparison: ECNR90, FRNR90

Item

ECNR90 - 90A 250V Class RK5 Time Delay CL Fuse - Edison

ECNR90
90A 250V Class RK5 Time Delay CL Fuse

$46.21 Each

$231.05 (5 Each)

QTY:
Each
Add
FRNR90 - 90A 250V Dual Elem RK5 TD Fuse Fusetron - Eaton Bussmann Series

FRNR90
90A 250V Dual Elem RK5 TD Fuse Fusetron

$58.65 Each

$293.25 (5 Each)

QTY:
Each
Add
Nacogdoches 0 0
All Stores 859 42
Vendor Edison Eaton Bussmann Series
Catalog Number ECNR90 FRNR90
Manufacturer Number ECNR90 FRNR90
Category Distribution Fuses - Dual Element Distribution Fuses - Dual Element
Classification Fuses & Fuse Accessories Fuses & Fuse Accessories
UNSPSC 39121604 - Time delay fuses 39121606 - Cartridge fuses
UPC/EAN/GTIN 00782634507420 00051712507424
Weight per package 0.33 (lbs/each) 0.31 (lbs/each)
Description ECNR90 90A 250V Class RK5 Time Delay CL Fuse
Ul Class RK-5 Time Delay
FRNR90 90A 250V Dual Elem RK5 TD Fuse Fusetron
Eaton Bussmann Series Class RK5 Fuse, FRN-R, Time-Delay, Dual-Element, Current Limiting Fuse, 90 A, Non-Indicating Fuse, Interrupting Rating Of 200 Ka At 250 Vac
Minimum Order QTY 1 Unit 1 Unit
Unit/Foot $46.21 (Each) $58.65 (Each)
Carton/Reel $46.21 (1 Each) $293.25 (5 Each)
Standard Packaging/Reel $231.05 (5 Each) $293.25 (5 Each)
Characteristics 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT -
Current Rating 90 AMPERE -
Interrupting Rating 200 KILOAMPERE (SYMMETRICAL) -
Terminal Type Blade -
Voltage Rating 250 VAC -
Diameter 1.06 INCH -
Length 5.88 INCH -
Additional Information Application Branch and Feeder Circuit, AC Drive, Loadcenter, Panel Board and Switch Board, Non-Inductive Load, General Purpose, Lighting and Heating -
Commodity Description DUAL ELEMENT FUSES -
Description 90A 250V CLASS RK5 TIME DELAY CL FUSE 90A 250V DUAL ELEM RK5 TD FUSE FUSETRON
extra long description CLASS RK5 TYPE; 5.88 INCH; UL, CSA C22.2, CE APPROVAL; 250 VOLT AC, 125 VOLT DC VOLTAGE RATING; 1.06 INCH DIAMETER; 200 KILOAMP (SYMMETRICAL) INTERRUPTING RATING; 90 AMP CURRENT RATING; BLADE TERMINAL TYPE; 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS; APPLICATION AC POWER DISTRIBUTION SYSTEM MAINS, FEEDERS AND BRANCH CIRCUITS, PROTECTION OF MOTORS AND MOTOR BRANCH CIRCUITS, TRANSFORMERS AND OTHER INDUCTIVE LOADS, LIGHTING, HEATING AND OTHER NON-INDUCTIVE LOADS; ECNR MODEL BUSS FRN-R-90 FUSETRON DUAL-ELEMENT
Features - Bussmann's UL Class RK5 Fusetron product offering provides energy efficient advanced protection with its dual-element, time-delay construction and is available with optional open fuse indication on select ratings. Available in both 250Vac and 600Vac, 200kA RMS Sym interrupting rating and sizes ranging from 0 to 600 amp. Fusetron's deliver 10 seconds (minimum) of time-delay at 500 of rated current (8 seconds for 1/10-30A sizes).
Long Description UL CLASS RK-5 TIME DELAY Eaton Bussmann Series Class RK5 fuse, FRN-R, time-delay, dual-element, current limiting fuse, 90 A, non-indicating fuse, interrupting rating of 200 kA at 250 Vac
Product Type Power Fuse Fusetron Dual-Element Class RK5
media - Yes
Brand EDISON Eaton Bussmann series
Manufacturers Part Number ECNR90 FRN-R-90
Model ECNR -
Category Description Fuses & Fuse Accessories Fuses & Fuse Accessories
Type CLASS RK5 -
Manufacturer Status Non-Stock -
Approval UL, CSA C22.2, CE -
 
QTY:
Each
Add
QTY:
Each
Add