Item Comparison: FRSR30, FLSR30ID

Item

FRSR30 - 30A 600V TD Class RK5 Dual Elem Fuse-Fusetron - Eaton

FRSR30
30A 600V TD Class RK5 Dual Elem Fuse-Fusetron

$29.95 Each

$299.50 (10 Each)

QTY:
Each
Add
FLSR30ID - 30A 600V Ul Class RK5 Dual Element TD Fuse - Littelfuse

FLSR30ID
30A 600V Ul Class RK5 Dual Element TD Fuse

$35.89 Each

$35.89 (1 Each)

QTY:
Each
Add
Nacogdoches 0 0
All Stores 322 3
Vendor Eaton Littelfuse
Catalog Number FRSR30 FLSR30ID
Manufacturer Number FRS-R-30 FLSR030ID
Category Distribution Fuses - Dual Element Distribution Fuses - Dual Element
Classification Fuses & Fuse Accessories Fuses & Fuse Accessories
UNSPSC 39121606 - Cartridge fuses 39121627 - Power fuse
UPC/EAN/GTIN 00051712508346 00079458025408
Weight per package 0.16 (lbs/each) 0.16 (lbs/each)
Description FRSR30 30A 600V TD Class RK5 Dual Elem Fuse-Fusetron
Eaton Bussmann Series FRS-R Fuse, 30 A, Dual, Class RK5, Non-Indicating, Ferrule End X Ferrule End, 10 Sec At 500%, 20 Kaic At 300 VDC 200 Kaic At 600 V, Standard, 600 V, 300 VDC
FLSR30ID 30A 600V Ul Class RK5 Dual Element TD Fuse
Time Delay Power Fuse, RK5 Class Fuse, Ferrule Fuse, 30 A, 600 V Ac;300 V DC, Ferrule Terminal, Blown Fuse Indicator, 13/16 In Diameter, 5 In Overall Length, 0.16 LB
Minimum Order QTY 1 Unit 1 Unit
Unit/Foot $29.95 (Each) $35.89 (Each)
Carton/Reel $299.50 (10 Each) $35.89 (1 Each)
Standard Packaging/Reel $299.50 (10 Each) $35.89 (1 Each)
amperage rating 30 A -
connection Ferrule End X Ferrule End -
Current Rating 30 A 30 A
interrupt rating 20 kAIC at 300 Vdc200 kAIC at 600 Vac Ac:200;300 kAIC Rms (Symmetrical);DC:20 kAIC
Terminal Type Ferrule Ferrule
Voltage Rating 600 Vac, 300 Vdc 600 V ac;300 V dc
Diameter 0.81 in 13/16 in;20.6 mm
Overall Length 5 in 5 in;127 mm
Size 0.81 In Diameter X 5.00 In Length -
Description 30A 600V TD CLASS RK5 DUAL ELEM FUSE-FUSETRON 30A 600V UL CLASS RK5 DUAL ELEMENT TD FUSE
extra long description BUSS FRS-R-30 FUSETRON DUAL ELEMENT L-FSE FLSR030ID FUS 600V T/D CLASS
Features Advanced protection, energy efficient Class RK5 dual-element, current-limiting, time-delay fuses with optional open fuse indication on select ratings. Time-delay — 10 second (minimum) at 500% of rated current. Littelfuse FLSR_ID Indicator(TM) fuses provide visual blown fuse indication at a glance. The patented state-of-the-art solid state design provides maximum reliability and superior performance characteristics in a true dual-element design. The use of Indicator fuses reduces down-time, nuisance opening, increases safety, and can save thousands of dollars in lost production time.
Long Description Eaton Bussmann series FRS-R fuse, 30 A, Dual, Class RK5, Non-indicating, Ferrule end x ferrule end, 10 sec at 500%, 20 kAIC at 300 Vdc 200 kAIC at 600 V, Standard, 600 V, 300 Vdc Time Delay Power Fuse, RK5 Class Fuse, Ferrule Fuse, 30 A, 600 V ac;300 V dc, Ferrule Terminal, Blown Fuse Indicator, 13/16 in Diameter, 5 in Overall Length, 0.16 lb
Product Type Fusetron Dual Element Fuse Class RK5 Fus 600V T/D Class RK5 30A Indicating
Short Description Fusetron Fuse, 30 A, 600 VAC/300 V dc, Time Delay, RK5 Class Power Fuse, 30 A, 600 VAC/300 V dc, Time Delay, RK5 Class, ID
Special Features NOT RENEWABLE Time-Delay
BLOWN FUSE INDICATOR - Yes
class Class RK5 -
Connection Type Ferrule End x Ferrule End -
dimensions 11.6300 IN X 2.3400 IN X 2.3400 IN -
element Dual -
Fuse Class RK5 Class RK5 Class
Fuse Type Dual Element Ferrule
media Yes -
package quantity 10 CT 1 CT;10 PK
Response Time 10 S at 500% -
Standards Met UL Listed;STD. 248-12;Class RK5;Guide JDDZ, File E4273;CSA Certified;C22.2 No. 248.12, Class 1422-02, File 53787;CE Certified UL Listed 248-12;UL Listed (File:E81895);CSA Certified (File:LR29862);Federal Specification WF-1814 (QPL- W-F-1814);QPL;CE Certified
Made in USA yes yes
Brand Eaton Powr-Gard(R)
Manufacturers Part Number FRS-R-30 FLSR030ID
sub brand - POWR-GARD FLSR Series
Category Description Fuses & Fuse Accessories Fuses & Fuse Accessories
Type FUSE CLASS RK5
Weight 0.16 lb 0.16 lb
Application Ind Facilities & Factories - Facility: Safety and Security Systems Service Entrance Switches;Switchboard Main and Feeder Switches;Transformers;Motor Control Center Mains and Motor Branch Circuits;individual Fused Combination Motor Controllers;Distribution Panelboards;industrial Control Panels;Protection of Fully-Rated Panelboards and Loadcenters;All General Purpose Circuits
standard CE Marked Standard 248-12 UL Listed/CSA
 
QTY:
Each
Add
QTY:
Each
Add