Item Comparison: ECSR90, TRS90R

Item

ECSR90 - 90A 600V Class RK5 Time Delay CL Fuse - Edison

ECSR90
90A 600V Class RK5 Time Delay CL Fuse

$78.50 Each

$392.50 (5 Each)

QTY:
Each
Add
TRS90R - 600V 90A 7 7/8X1 5/16 TD Fuse - Mersen

TRS90R
600V 90A 7 7/8X1 5/16 TD Fuse

$0.00 Each

$0.00 (5 Each)

Call nearest store for Item Price
Nacogdoches 0 0
All Stores 297 1
Vendor Edison Mersen
Catalog Number ECSR90 TRS90R
Manufacturer Number ECSR90 TRS90R
Category Distribution Fuses - Dual Element Distribution Fuses - Current Limiting
Classification Fuses & Fuse Accessories Fuses & Fuse Accessories
UNSPSC 39121604 - Time delay fuses 39121604 - Time delay fuses
UPC/EAN/GTIN 00782634508427 00782001749101
Weight per package 0.41 (lbs/each) 0.68 (lbs/each)
Description ECSR90 90A 600V Class RK5 Time Delay CL Fuse
Ul Class RK-5 Time Delay
TRS90R 600V 90A 7 7/8X1 5/16 TD Fuse
Fuse TRS-R - Class RK5 - Time-Delay 600VAC 600VDC 90A Blade Tri-Onic®
Minimum Order QTY 1 Unit 1 Unit
Unit/Foot $78.50 (Each) $0.00 (Each)
Carton/Reel $78.50 (1 Each) $0.00 (1 Each)
Standard Packaging/Reel $392.50 (5 Each) $0.00 (5 Each)
amperage rating - 90
Characteristics 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT -
connection - Blade
Current Rating 90 AMPERE -
interrupt rating - 200
Interrupting Rating 200 KILOAMPERE (SYMMETRICAL) -
Terminal Type Blade -
Voltage Rating 600 VAC 600
Body Material - PolyTube
Diameter 1.11 INCH -
Length 7.88 INCH -
Size - 7.88 x 1.31
Additional Information Application Branch and Feeder Circuit, AC Drive, Loadcenter, Panel Board and Switch Board, Non-Inductive Load, General Purpose, Lighting and Heating -
Commodity Description DUAL ELEMENT FUSES -
Description 90A 600V CLASS RK5 TIME DELAY CL FUSE 600V 90A 7 7/8X1 5/16 TD FUSE
extra long description CLASS RK5 TYPE; 7.88 INCH; UL, CSA C22.2, CE APPROVAL; 600 VAC VOLTAGE RATING; 1.11 INCH DIAMETER; 200 KILOAMPERE (SYMMETRICAL) INTERRUPTING RATING; 90 AMPERE CURRENT RATING; BLADE TERMINAL TYPE; 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS; APPLICATION BRANCH AND FEEDER CIRCUIT, AC DRIVE, LOADCENTER, PANEL BOARD AND SWITCH BOARD, NON-INDUCTIVE LOAD, GENERAL PURPOSE, LIGHTING AND HEATING; ECSR MODEL Mersen TRS90R Fuse TRS-R - Class RK
Features - Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.
Long Description UL CLASS RK-5 TIME DELAY Fuse TRS-R - Class RK5 - Time-Delay 600VAC 600VDC 90A Blade Tri-Onic®
Product Type Power Fuse Fuse TRS-R - Class RK5 - Time-Delay 600VAC 600VDC 90A Blade
Short Description - 600V 90A 7 7/8x1 5/16 TD
Special Features - Time-delay Current-limiting AC & DC rated Optional solid state SmartSpot blown fuse indicator Time-delay for motor start-ups and transformer inrush currents without nuisance opening Current-limiting for low peak let-thru current Rejection-style design prevents replacement errors (when used with recommended fuse blocks) Easy-to-read label for quick brand recognition and replacement Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stabili
AC Voltage Rating - 600
class - Class RK5
Brand EDISON Mersen
Manufacturers Part Number ECSR90 TRS90R
Model ECSR -
Category Description Fuses & Fuse Accessories Fuses & Fuse Accessories
Type CLASS RK5 CLASS RK5
Manufacturer Status Non-Stock -
Application - Motor circuits Mains Feeders Branch circuits Transformers Service entrance equipment General-purpose equipment
Approval UL, CSA C22.2, CE -
Mounting - Clip
standard - UL listed to standard 248-12 File E2137 CSA certified to standard C22.2 no. 248.12 DC listed to UL standard 248 TRS only
 
QTY:
Each
Add
Call nearest store for Item Price