Item Comparison: BR3030, BD3030

Item

BR3030 - BR Duplex BRKR 2-30A/1 Pole 120/240V 10K Non-CTL - Eaton

BR3030
BR Duplex BRKR 2-30A/1 Pole 120/240V 10K Non-CTL

$49.06 Each

$490.60 (10 Each)

QTY:
Each
Add
BD3030 - Type BD Duplex BRKR 2-30A/1 Pole 120/240V 10K - Eaton

BD3030
Type BD Duplex BRKR 2-30A/1 Pole 120/240V 10K

$51.25 Each

$51.25 (1 Each)

QTY:
Each
Add
Nacogdoches 2 0
All Stores 452 68
Vendor Eaton Eaton
Catalog Number BR3030 BD3030
Manufacturer Number BR3030 BD3030
Category Standard Trip Plug - Duplex Standard Trip Plug-In Standard Trip Plug - Duplex Standard Trip Plug-In
Classification Specialty Breakers (Quad, Dupl, Shunt Trip) Loadcenter Plug In Breakers and Accessories
UNSPSC 39121601 - Circuit breakers 39121601 - Circuit breakers
UPC/EAN/GTIN 00786676370301 00786676369503
Weight per package 0.35 (lbs/each) 0.4 (lbs/each)
Description BR3030 BR Duplex BRKR 2-30A/1 Pole 120/240V 10K Non-CTL
Non CTL Plug On Circuit Breaker, 30 A, 2 Poles, Common Tripping Mechanism, Line and Load Lug Terminal, Plug-On, 120/240 V, 3 In Overall Height, 3 In Overall Length, 1 In Overall Width
BD3030 Type BD Duplex BRKR 2-30A/1 Pole 120/240V 10K
Eaton BR Thermal Magnetic Circuit Breaker, Type BD 1-Inch CTL Plug-On Breaker, Includes Rejection Tab Feature, 30-30 A, 10 Kaic, Single-Pole, 120V, BD, #14-4 Awg Cu/Al, BD, Type BR Loadcenters
Minimum Order QTY 1 Unit 1 Unit
Unit/Foot $49.06 (Each) $51.25 (Each)
Carton/Reel $49.06 (1 Each) $51.25 (1 Each)
Standard Packaging/Reel $490.60 (10 Each) $51.25 (1 Each)
Current Rating 30 A -
interrupt rating 10 kAIC 10 kAIC
Poles Three-pole Single-pole
Voltage Rating 120/240 V 120 V
Overall Length 3 in -
Description BR DUPLEX BRKR 2-30A/1 POLE 120/240V 10K NON-CTL TYPE BD DUPLEX BRKR 2-30A/1 POLE 120/240V 10K
extra long description ETN BR3030 BR Duplex 2-30A/1 Pole 1 ETN BD3030 BD Duplex 2-30A/1 Pole 1
Features A branch feeder type arc fault circuit interrupter is a device intended to mitigate high current arcing faults in the complete circuit, including connected cords. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults.The branch feeder type AFCI is required in the 1999 and 2002 National Electrical Code. The Combination Type AFCI is required in the 2005, 2008, and 2011 National Electrical Eaton's residential BR Circuit Breakers are used in load centers, panelboards, or similar devices. They are made for a wide range of applications and include: BR 1" circuit breakers and accessories for BR-style load centers; arc fault circuit interrupters (AFCI); and ground fault circuit interrupters (GFCI).
Long Description Non CTL Plug on Circuit Breaker, 30 A, 2 Poles, Common Tripping Mechanism, Line and Load Lug Terminal, Plug-On, 120/240 V, 3 in Overall Height, 3 in Overall Length, 1 in Overall Width Eaton BR thermal magnetic circuit breaker,Type BD 1-Inch CTL plug-on breaker,Includes rejection tab feature,30-30 A,10 kAIC,Single-pole,120V,BD,#14-4 AWG Cu/Al,BD,Type BR Loadcenters
Product Type Non CTL Plug on Circuit Breaker BD Duplex 2-30A/1 Pole 120/240V 10K
Short Description Non CTL Plug on Circuit Breaker, 30 A, 120/240 V -
Special Features - Includes Rejection Tab feature
circuit breaker type Non CTL Plug on Circuit Breaker -
dimensions 1.0000 IN X 2.9000 IN X 2.5000 IN 2.9000 IN X 1.0000 IN X 2.5000 IN
for use with Type BR Loadcenters -
Mounting Type Plug-On -
Overall Height 3 in -
Overall Width 1 in -
Standards Met UL Listed 489;Federal Specifications Classification W-C375;IGCC 4813 -
Terminal Connection Type Line and Load Lug -
Trip Type Common breaker trip -
Tripping Mechanism Common -
Brand Eaton Corp Eaton
Manufacturers Part Number BR3030 BD3030
Category Description Specialty Breakers (Quad, Dupl, Shunt Trip) Loadcenter Plug In Breakers and Accessories
Type Thermal magnetic circuit breakers Thermal magnetic circuit breakers
Application Datacenters - IT Space: CI and Hyper ConvergedOtherMarine Vessels and Equipment - Marine Vessels and Equipment - OtherGeneration - Renewable Energy - Alternative EnergyGeneration - Conventional Energy - Conventional Energy OtherMarine Vessels and Equipment - Marine Vessels and Equipment - OtherGeneration - Renewable Energy - Alternative EnergyGeneration - Conventional Energy - Conventional EnergyDatacenters - IT Space: CI and Hyper Converged
standard UL 489,Federal Specifications Classification W-C375 UL 489,Federal Specifications Classification W-C375
 
QTY:
Each
Add
QTY:
Each
Add

Begin Live Chat