Item Comparison: CHF150, CH150

Item

CHF150 - Type CHF BRKR 50A/1P 120/240V 10kaic - Eaton

CHF150
Type CHF BRKR 50A/1P 120/240V 10kaic

$13.44 Each

$134.40 (10 Each)

QTY:
Each
Add
CH150 - 1P 50A 120V Breaker - Eaton

CH150
1P 50A 120V Breaker

$13.44 Each

$13.44 (1 Each)

QTY:
Each
Add
Nacogdoches 0 0
All Stores 560 0
Vendor Eaton Eaton
Catalog Number CHF150 CH150
Manufacturer Number CHF150 CH150
Category Standard Trip Plug - 1 Pole Standard Trip Plug-In Standard Trip Plug - 1 Pole Standard Trip Plug-In
Classification Loadcenter Plug In Breakers and Accessories Loadcenter Plug In Breakers and Accessories
UNSPSC 39121603 - Miniature circuit breakers 39121601 - Circuit breakers
UPC/EAN/GTIN 00786685532141 00782113101682
Weight per package 0.25 (lbs/each) 0.28 (lbs/each)
Description CHF150 Type CHF BRKR 50A/1P 120/240V 10kaic
Standard Trip Circuit Breaker, 50 A, Common Tripping Mechanism, Plug-On, 120/240 V Ac, 3 In Overall Height, 3 In Overall Length, 0.75 In Overall Width, 0.25 LB
CH150 1P 50A 120V Breaker
Eaton Type CH 3/4-Inch Standard Circuit Breaker, Type CH 3/4-Inch Standard Circuit Breaker, 50 A, 10 Kaic, Single-Pole, 120/240V, CH, #14-2 Awg Cu/Al, CH, Type CH Loadcenters
Minimum Order QTY 1 Unit 1 Unit
Unit/Foot $13.44 (Each) $13.44 (Each)
Carton/Reel $13.44 (1 Each) $13.44 (1 Each)
Standard Packaging/Reel $134.40 (10 Each) $13.44 (1 Each)
amperage rating 50 A -
Current Rating 50 A -
interrupt rating 10 kAIC 10 kAIC
Poles Single-pole Single-pole
Voltage Rating 120/240 V ac 120/240 V
Height - 3 in
Length - 3.5 in
Overall Length 3 in -
Width - 5 in
Description TYPE CHF BRKR 50A/1P 120/240V 10KAIC 1P 50A 120V BREAKER
extra long description ETN CHF150 CHF BREAKER, 50A / 1P 12 ETN CH150 CH15096-4604-11Type CH Br
Features Quick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip- free handle design. Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multipole breakers have internal common trip co Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneous
Long Description Standard Trip Circuit Breaker, 50 A, Common Tripping Mechanism, Plug-On, 120/240 V ac, 3 in Overall Height, 3 in Overall Length, 0.75 in Overall Width, 0.25 lb Eaton Type CH 3/4-Inch Standard Circuit Breaker,Type CH 3/4-Inch standard circuit breaker,50 A,10 kAIC,Single-pole,120/240V,CH,#14-2 AWG Cu/Al,CH,Type CH Loadcenters
Product Type Standard Trip Circuit Breaker CH15096-4604-11TYPE CH Breaker 50A/1 Pole 120/240V 10K
Short Description 2P Standard Trip Circuit Breaker, 50 A, 120/240 VAC w/Trip Flag -
circuit breaker type Standard Trip Circuit Breaker -
dimensions 3.0000 IN X 0.7500 IN X 3.0000 IN -
for use with Type CH Loadcenters -
Mounting Type Plug-On -
Overall Height 3 in -
Overall Width 0.75 in -
Standards Met UL 489 Listed;IGCC 4813 -
Trip Type Trip flag -
Tripping Mechanism Common -
Brand Eaton Corp Eaton
Manufacturers Part Number CHF150 CH150
Category Description Loadcenter Plug In Breakers and Accessories Loadcenter Plug In Breakers and Accessories
Type Thermal magnetic circuit breakers Thermal magnetic circuit breakers
Status - Inactive
Weight 0.25 lb -
Application Generation - Conventional Energy - Conventional EnergyMarine Vessels and Equipment - Marine Vessels and Equipment - OtherOtherGeneration - Renewable Energy - Alternative EnergyDatacenters - IT Space: CI and Hyper Converged -
standard UL 489,HACR Rated UL 489
 
QTY:
Each
Add
QTY:
Each
Add

Begin Live Chat