Item Comparison: ECNR10, TR10R

Item

ECNR10 - 10A 250V Class RK5 Time Delay CL Fuse - Edison

ECNR10
10A 250V Class RK5 Time Delay CL Fuse

$15.47 Each

$154.70 (10 Each)

QTY:
Each
Add
TR10R - 250V 10A 2X9/16 RK5 TD Fuse - Mersen

TR10R
250V 10A 2X9/16 RK5 TD Fuse

$0.00 Each

$0.00 (10 Each)

Call nearest store for Item Price
Nacogdoches 42 0
All Stores 928 4
Vendor Edison Mersen
Catalog Number ECNR10 TR10R
Manufacturer Number ECNR10 TR10R
Category Distribution Fuses - Dual Element Distribution Fuses - Current Limiting
Classification Fuses & Fuse Accessories Fuses & Fuse Accessories
UNSPSC 39121604 - Time delay fuses 39121604 - Time delay fuses
UPC/EAN/GTIN 00782634507284 00782001747800
Weight per package 0.05 (lbs/each) 0.05 (lbs/each)
Description ECNR10 10A 250V Class RK5 Time Delay CL Fuse
Ul Class RK-5 Time Delay
TR10R 250V 10A 2X9/16 RK5 TD Fuse
Fuse TR-R - Class RK5 - Time-Delay 250VAC 160VDC 10A Ferrule Tri-Onic®
Minimum Order QTY 1 Unit 1 Unit
Unit/Foot $15.47 (Each) $0.00 (Each)
Carton/Reel $15.47 (1 Each) $0.00 (1 Each)
Standard Packaging/Reel $154.70 (10 Each) $0.00 (10 Each)
amperage rating - 10
Characteristics 8 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT -
connection - Ferrule
Current Rating 10 AMPERE -
interrupt rating - 200
Interrupting Rating 200 KILOAMPERE (SYMMETRICAL) -
Terminal Type Ferrule -
Voltage Rating 250 VAC, 125 VDC 250
Body Material - PolyTube
Diameter 0.56 INCH -
Length 2 INCH -
Size - 2 x 0.56
Additional Information Application Branch and Feeder Circuit, AC Drive, Loadcenter, Panel Board and Switch Board, Non-Inductive Load, General Purpose, Lighting and Heating -
Commodity Description DUAL ELEMENT FUSES -
Description 10A 250V CLASS RK5 TIME DELAY CL FUSE 250V 10A 2X9/16 RK5 TD FUSE
extra long description CLASS RK5 TYPE; 2 INCH; UL, CSA C22.2, CE APPROVAL; 250 VAC, 125 VDC VOLTAGE RATING; 0.56 INCH DIAMETER; 200 KILOAMPERE (SYMMETRICAL) INTERRUPTING RATING; 10 AMPERE CURRENT RATING; FERRULE TERMINAL TYPE; 8 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS; APPLICATION BRANCH AND FEEDER CIRCUIT, AC DRIVE, LOADCENTER, PANEL BOARD AND SWITCH BOARD, NON-INDUCTIVE LOAD, GENERAL PURPOSE, LIGHTING AND HEATING; ECNR MODEL Mersen TR10R Fuse TR-R - Class RK5
Features - Tri-Onic TR-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TR-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.
Long Description UL CLASS RK-5 TIME DELAY Fuse TR-R - Class RK5 - Time-Delay 250VAC 160VDC 10A Ferrule Tri-Onic®
Product Type Power Fuse Fuse TR-R - Class RK5 - Time-Delay 250VAC 160VDC 10A Ferrule
Short Description - 250V 10A 2x9/16 RK5 TD FU
Special Features - Time-delay Current-limiting AC & DC rated Optional solid state SmartSpot blown fuse indicator Time-delay for motor start-ups and transformer inrush currents without nuisance opening Current-limiting for low peak let-thru current Rejection-style design prevents replacement errors (when used with recommended fuse blocks) Easy-to-read label for quick brand recognition and replacement Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stabili
AC Voltage Rating - 250
class - RK-5
Brand EDISON Mersen
Manufacturers Part Number ECNR10 TR10R
Model ECNR -
sub brand - Tri-Onic®
Category Description Fuses & Fuse Accessories Fuses & Fuse Accessories
Type CLASS RK5 CLASS RK5
Manufacturer Status Non-Stock -
Application - Motor circuits Mains Feeders Branch circuits Transformers Service entrance equipment General-purpose equipment
Approval UL, CSA C22.2, CE -
Mounting - Clip
standard - UL listed to standard 248-12 File E2137 CSA certified to standard C22.2 no. 248.12 DC listed to UL standard 248 TRS only
 